<LOGO>
FM Transmitter Measurement Report
Created: 2025-07-27 20-33-30
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.20 MHz 5/5, 58 dBuV YLEX
Pilot RDS Phase Difference
7.2 kHz 2.2 kHz 60 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 64 kHz 19080 3,2233
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
4,9 dBr 5,36 dBr 6,0 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLEX " 6202 10 (Pop M) 0 1 1 1 20:33, 27.07.2025
RT
"YleX Vaihtoehto: Raine Laaksonen "
AF EON
91.5, 91.8, 91.9, 92.6, 93.2, 94.3, 96.1 MHz 6201, 6203, 6207, 6205
FM Scope Max at: 64 kHz MIN: 10 kHz % above 76 kHz: 3,2233 Acquired: 2025/07/27 20.32.27 Total samples: 19080 Equivalent time: 0:15:54 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 6,0 dBr MIN: 4,9 dBr AVE: 5,36 dBr % above 12,2 dBr: 0,0 Last value: 5,4 dBr (2025/07/27 20.32.26) 20.18 20.20 20.22 20.24 20.26 20.28 20.30 20.32 0 2 4 6 Pm [dBr]